Fluke Calibration's new class of multi-product calibrator
FAQ
Precision, Performance, Confidence.®
Experience the next level of multi-product calibrators
The new Fluke Calibration 5560A, 5550A, and 5540A High Performance Multi-Product Calibrators are designed to meet and expand your laboratory workload.

A new class of calibrator

Accuracy, throughput, and workload coverage are the most important contributors to a calibration lab's success. The new Fluke Calibration Multi-Product Calibrators are capable of handling larger workloads than anything previously and more accurately than anything currently available.

All-new features of the 5560A/5550A/5540A Multi-Product Calibrators

  • 4:1 test uncertainty ratio (TUR) for most popular 6.5 digit multimeters
  • 30 A continuous current output to extend AC/DC measurement ranges
  • Calibrate AC/DC voltage, current, resistance, capacitance, and inductance and more
  • Oscilloscope calibration option up to a 2.1 GHz range
  • Automate with MET/CAL™ Calibration Management Software
  • 7-inch color touch screen

A new class of calibrator

Accuracy, throughput, and workload coverage are the most important contributors to a calibration lab's success. The new Fluke Calibration Multi-Product Calibrators are capable of handling larger workloads than anything previously and more accurately than anything currently available.

All-new features of the 5560A/5550A/5540A Multi-Product Calibrators

  • 4:1 test uncertainty ratio (TUR) for most popular 6.5 digit multimeters
  • 30 A continuous current output to extend AC/DC measurement ranges
  • Calibrate AC/DC voltage, current, resistance, capacitance, and inductance and more
  • Oscilloscope calibration option up to a 2.1 GHz range
  • Automate with MET/CAL™ Calibration Management Software
  • 7-inch color touch screen

Even further expand your workload coverage

All-new scope calibration option, available now.

DC and LF electrical functions along with an RF voltage source includes everything you need to calibrate an oscilloscope. Designed with fast edge, markers, and frequences of more than 600 MHz, 1 GHz, and a 2 GHz range.

600 MHz 1 GHz 2 GHz
5560A
5550A
5540A

Experience the power of doing more with less

Advanced technology streamlines your workflow. Save time and resources with more efficient processes while delivering exceptional accuracy and reliability.

With redesigned ranging, one calibrator can do more
The 5560A, 5550A, and 5540A are optimized to match the range switching of 6.5-digit, 5.5-digit, and 4.5-digit mulitimeters. The 5522A was designed to range in multiples of 3.3x. Our new calibrators range at 1.2x, matching digital multimeters at their ideal specification points. With these improvements, calibrate more of your multimeter workload with a single calibrator, with more confidence.

Faster settling time
Settling time for the 5560A, 5550A, and 5540A is up to 50% faster than the 5522A. Almost as soon as you push operate, the calibrator is ready to go. A few seconds saved on each measurement adds up quickly.

Continuous 30 A current output with no downtime
All models include a 30 A continuous current output, which can run uninterrupted without a duty cycle. While other calibrators may need to shut down for seven minutes for every minute of use, our new calibrator doesn’t overheat, even over hours of heavy use. Less wait time, better throughput.

Thermocouple connector
The engineering team at Fluke Calibration developed a Universal Thermocouple Connector for these calibrators. The connection point can fit any connector with a spring fitting. Without creating friction each time you plug in a connector, you can move through your workload that much faster.

Easy for everyone in the lab to use and learn

A patented, new touchscreen interface and updated UI make the new calibrators more intuitive than previous Fluke calibrators.

Modern touchscreen user interface
The menu-driven interface of the 5522A has been replaced by a 7-inch graphical user interface that is intuitive and easy to read, displaying only the information you need for each procedure.
Visual Connection Management™ terminals
Output terminals light up to show you which terminals are active. Green for voltage, and blue for current, making it easier to match the right connections to the measurement you’re making.
Remapped output terminal block layout
Connect leads once and complete calibrations efficiently. We’ve redesigned the output block to match the layout on standard digital multimeters and to minimize lead changes with dedicated terminals.
Reverse power protection without false tripping
Reverse power protection and immediate output disconnection on the output terminals protects the calibrator’s internal circuitry, preventing damage and keeping the calibrator up and running.

Try the Visual Connnection Management interactive demo

As you select different functions in the interactive demo below, observe how the connection terminals light up to guide users to the correction connections for the procedure being performed.

Voltage Current Amps Thermocouples Resistance Resistance 2 or 4 wire
AC DC AC DC Lo Hi

Click through the functions on this interactive demo to see the effects of Visual Connection Management on the terminals. When you're ready to see it in person, talk to a Fluke expert now to request a live demo.


Redesigned accessories and simplified automation

In the lab or on-site, features you expect from a modern calibration instrument.

Optional portability kit for calibration in the field

For those who work in the field, the portability kit protects the calibrator and makes it easier to transport. The kit includes front/rear bumpers and an easy-grip side handle. A transit case (included) is designed for shipping the calibrator, with or without the portability kit.


Higher throughput for high current workloads

The increased 30 A output enables you to use the 5560A, 5550A, and 5540A as a 30 A calibrator for higher current workloads, such as clamp meters up to 1500 A (with optional current coil). Continuous output means you don’t need to put the calibrator on standby for cool down periods while using the current function.

Redesigned accessories and simplified automation

In the lab or on-site, features you expect from a modern calibration instrument.

Safer, more ergonomic, less susceptible to damage. Fluke Calibration engineers have improved accessories and automation to expand your workload and get more done in a day.


Optional portability kit for calibration in the field

For those who work in the field, the portability kit protects the calibrator and makes it easier to transport. The kit includes front/rear bumpers and an easy-grip side handle. A transit case (included) is designed for shipping the calibrator, with or without the portability kit.


Higher throughput for high current workloads

The increased 30 A output enables you to use the 5560A, 5550A, and 5540A as a 30 A calibrator for higher current workloads, such as clamp meters up to 1500 A (with optional current coil). Continuous output means you don’t need to put the calibrator on standby for cool down periods while using the current function.

Redesigned current coils

A new optional 1-, 2-, 10-turn current coil and a redesigned 50-turn current coil work with the 5560A, 5550A, and 5540A to enable you to calibrate workload that includes clamp-type current meters and oscilloscope current probes. Each coil, like the calibrator, is designed for continuous use at 30 A with a minimum duty cycle which improves calibration throughput as much as four times.


Expand workload coverage even more. Use the 5560A, 5550A, or the 5540A with the Fluke Calibration 52120A Transconductance Amplifier to increase the current output to 6000 A, ideal for calibrating high-current components such as Rogowski coils.

Expand your capabilities even further

Get the most from the 5560A, 5550A and 5540A with these additions to your laboratory.

MET/CAL™ automation increases throughput and efficiency

The 5560A, 5550A and 5540A work with MET/CAL, including hundreds of automated calibration procedures to consistently and dramatically improve throughput. MET/CAL v10.6.2 and later includes a Function Select Code (FSC) that enables you to add the 5560A, 5550A and 5540A seamlessly to your existing calibration operations.


Pair with the 8588A Reference Multimeter

The capabilities of the 5560A, 5550A, and 5540A paired with the 8558A or 8588A Reference Multimeter creates a powerful calibrator. Equip your lab with improved verfication and a simplified calibration adjustment process, push your lab's throughput even further.

Expand your capabilities even further

Get the most from the 5560A, 5550A and 5540A with these additions to your laboratory.

MET/CAL™ automation increases throughput and efficiency

The 5560A, 5550A and 5540A work with MET/CAL, including hundreds of automated calibration procedures to consistently and dramatically improve throughput. MET/CAL v10.6.2 and later includes a Function Select Code (FSC) that enables you to add the 5560A, 5550A and 5540A seamlessly to your existing calibration operations.


Pair with the 8588A Reference Multimeter

The capabilities of the 5560A, 5550A, and 5540A paired with the 8558A or 8588A Reference Multimeter creates a powerful calibrator. Equip your lab with improved verfication and a simplified calibration adjustment process, push your lab's throughput even further.


Measure more with the 52120A Transconductance Amplifier

Your workload is expanded even further when the 5560A is used with a 52120A Transconductance Amplifer to increase the current output to 6000 A, for calibrating high-current components such as Rogowski coils.



Three models to fit your application

All three models of the new multi-product calibrators are designed to provide exceptional accuracy and reliability.




5560A



5550A



5540A

The next generation high-performing calibrator supporting the widest workload coverage Optimized for your multimeter workload Better performance for on-site or mobile calibration
4:1 test TUR for most popular multimeters Up to 6.5 digits Up to 5.5 digits Up to 4.5 digits
30 A continuous current output extends AC/DC measurement ranges
Calibrate meters that measure AC/DC voltage, resistance and capacitance
Ranging optimized to better match your existing digital multimeter workload
New optional 1-, 2-, 10-turn and redesigned 50-turn current coils expand workload coverage even further
17.8 centimeter (7-inch) color touch screen with new graphical user interface provides an intuitive calibration experience
Optional DMM AUTOCAL Adapter to calibrate digital multimeters with minimal-to-no lead changes
Visual Connection Management output terminals guide connections, preventing connection errors
Reverse power protection prevents costly operator errors
Oscilloscope calibration options expand workload coverage Up to 2 GHz Up to 1 GHz Up to 600 MHz

Want to learn more? Request a free quote or consultation today.