| Sensors |
MEM (microphones) |
202 |
202 |
| Frequency band |
2 kHz to 64 kHz |
2 kHz to 100 kHz |
| Detection range¹ |
0.5 to > 100 meters (1.6 to > 393 feet) |
0.5 to > 150 meters (1.6 to > 492 feet) |
| Field of view (FOV) (typical) |
64° × 48° |
| Nominal frame rate |
25 FPS |
| Built-in digital camera (visible light) |
Field of view (FOV) (typical) |
64° × 48° |
| Focus |
50 cm to infinity (20 inch) |
| Zoom |
3X digital zoom |
| Resolution |
13 MP |
| Display |
Size |
7" anti-glare LCD with backlight, sunlight readable |
| Resolution |
1280 × 800 (1,024,000 pixels) |
| Touchscreen |
Capacitive |
| Acoustic image |
SoundMap™ acoustic imaging overlay |
| Image storage |
Storage capacity |
128 GB |
| Image format |
Blended visual and SoundMap™.JPG |
| Video format |
Blended visual and SoundMap™.MP4 |
| Video length |
Up to 5 minutes |
| Digital export |
USB-C for data transfer |
| Acoustic |
Measurement range (typical) |
20 kHz: -10.4 ~ 122 dB SPL
25 kHz: -24.7 ~ 122 dB SPL
31.5 kHz: -13 ~ 122 dB SPL
40 kHz: -10.7 ~ 122 dB SPL
50 kHz: 8 ~ 122 dB SPL
|
| Auto max/min dB gain |
Auto or user selectable max dB |
| Frequency band selection |
User selectable through user-made presets or manual entry |
| Capture mode |
Photo |
Yes |
Yes |
| Video |
Yes |
Yes |
| LeakQ™ |
Leak size scale, rate and cost estimation |
Leak size scale, rate and cost estimation |
| PDQ Mode™ |
- |
Yes |
| MecQ™ |
- |
Yes |
| Beacon |
Yes, works with Fluke SB140 SoundBeacon™ for airtightness detection |
| Thermal |
Yes, works with TC03A |
| Battery |
Battery |
Rechargeable and field replaceable Li-ion battery |
| Battery life |
> 7 hours (2 × 3.5hrs) |
| Battery charging time |
< 3 hours |
| Battery charging system |
Internal (USB-C) |
| Software |
Ease of use |
Intuitive user interface |
| Acoustics |
Show dB Scale |
On/off |
| Min/Max dB |
Max dB/Auto |
| Profiles |
Preset capture profiles |
| High frequency |
- |
Yes |
| Battery charging system |
Internal (USB-C) |
| Multiple sources |
Multi source |
| Battery charging system |
Internal (USB-C) |
| Palette: Colors |
3: Grayscale, Ironbow, and Blue-Red |
| Palette: Overly transparency |
Yes: 1–100 % |
| Grayscale mode |
Yes |
| Trend graphs |
Frequency and dB scale |
| Leak values |
Leak costs, Leak volume, LeakQ TM scale (1–10) |
| Annotation |
Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
| Photo notes |
Up to 4 photo notes for reference |
| Asset inspection status |
‘As left’, ‘As found’, ‘Undetermined’ |
| Asset ID |
Text input and automatic QR code based asset ID identification |
| Actions annotation |
Action requirement, priortity and notes |
| On-device reporting |
Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode) |
| Other |
Operating conditions, Weather notes |
| General specification |
Tripod holder/connector |
Yes: 1/4”-20 |
| USB |
2 × USB-C |
| Wireless |
Wi-Fi |
| Operating temperature |
-10 to 45 °C |
| Wireless |
Wi-Fi |
| Storage temperature C |
-20 to 70 ° |
| Operating altitude |
Up to 2000 m |
| Storage altitude |
Up to 12000 m |
| Relative humidity |
10 to 95 % RH, non-condensing |
| Size (H × W × L) |
235 × 154 × 46 mm |
| Weight (battery included) |
1,2 kg (2.6 pounds) |
| Ingress protection (IP) |
IP54 |
| Warranty |
2-year |
| Fluke Premium Care |
Premium Care Standard4 |
| Self-diagnostic notification |
Array-health test to identify when microphone array needs attention |
| Supported languages |
Arabic, Dutch, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chines |
Safety and environmental |
RoHS compliant |
Yes |
| General safety |
IEC 61010-1: Pollution degree 2 |
| Electromagnetic Compatibility (EMC) International |
IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A |
| Korea (KCC) |
Class A Equipment (Industrial Broadcasting and Communication) |
| USA (FCC) |
47 CFR 15 subpart |
| Radio Equipment Directive (2014/53/EU) (RED) |
Yes |